  • Repro_Pro
    replied to Lotem 800V Errors
    Problem RESOLVED.
    Replacing the Interlock board fixed the problem.
    This should have been obvious to the first Tec guy, strangely he ignored it...
    See more | Go to post
    Last edited by Repro_Pro; 05-21-2017, 06:10 AM.

    Leave a comment:


  • Repro_Pro
    replied to Lotem 800V Errors
    Hi Peter,
    You are correct - the blowers in the L-Box do not function.
    We realized we need to go upstream from there.
    However, trying to resolve this problem took up too much time, so...
    See more | Go to post

    Leave a comment:


  • Repro_Pro
    replied to Lotem 800V Errors
    Hi Chock,
    The schematics I have are Function/Block Diagrams, not detailed enough.
    Many thanks for your readiness to help, but I believe that only a veteran ex-Scitex/Creo/Kodak Lotem service...
    See more | Go to post

    Leave a comment:


  • Repro_Pro
    replied to Lotem 800V Errors
    Thank you Chock,
    By now we know that LEDs on 2 PS's should have lit after startup, but they didn't.
    We are still investigating......
    See more | Go to post

    Leave a comment:


  • Repro_Pro
    started a topic Lotem 800V Errors

    Lotem 800V Errors

    Hi guys,

    We have a Lotem 800V, 48 diodes, app ver. 3.20.01

    Following startup, the machine arrives at READY state.
    After a while we get "ATTENTION" errors:...