Recent content by JOJOPILE

  1. J

    ERROR IN Suprasetter A52/A74

    Dear Sir Can you give me complete wiring diagram for suprasetter A75 Backplane, ... please. My problem is that voltage of X104/A28 24V_sw is 0V and ACFB Board does not start Thanks a lot Louison Parick
  2. J

    ERROR IN Suprasetter A52/A74

    Dear Sir Can you give me complete wiring diagram for suprasetter A75 Backplane, ... please Thanks a lot Louison Parick
  3. J

    ERROR IN Suprasetter A52/A74

    Hello all, I have a suprasetter 74 and the acfb board does not start, I check all voltages and only 24V_Sw is not present on pin X104/A26. My question: is it possible that optocoupler is do default. what optocoupler to be replaceable on backplane. THank a lot
  4. J

    Part Suppliers for Suprasetter (Heidelberg)

    Hello all, I have a suprasetter 74 and the acfb board does not start, I check all voltages and only 24V_Sw is not present on pin X104/A26. My question: is it possible that optocoupler is do default. what optocoupler in consequence to be replaceable on backplane. THank a lot
  5. J

    ERROR IN Suprasetter A52/A74

    The CTP is like on security mode as door open or the is no door open
  6. J

    ERROR IN Suprasetter A52/A74

    Hello Thanks a lot for replying me my mail is [email protected]. My mail is I think the 2 errors - Recorder error 101 : internal system error - Recorder error 2 : internal system error concern file error in the recorder. I don't know where find true file (name and version) and how to...
  7. J

    ERROR IN Suprasetter A52/A74

    Hello all Thanks a lot for replying me my mail is [email protected]. I think the 2 errors - Recorder error 101 : internal system error - Recorder error 2 : internal system error concern file error in the recorder. I don't know where find true file (name and version) and how to install it to...
  8. J

    ERROR IN Suprasetter A52/A74

    What is your condition. I must absolutelly repair this Supra A75
  9. J

    ERROR IN Suprasetter A52/A74

    Hello all Thanks a lot for replying me my mail is [email protected]. I think the 2 errors - Recorder error 101 : internal system error - Recorder error 2 : internal system error concern file error in the recorder. I don't know where find true file (name and version) and how to install it to...
  10. J

    ERROR IN Suprasetter A52/A74

    Hi I don't solve the problem, my suprasetter does the 2 errors: - Recorder error 101 : internal system error - Recorder error 2 : internal system error I see that ACFB module does not start Control Board D932.00 (Mod. 10 94V) does not start Servo motor...
  11. J

    Lotem 1, Slammer 0

    That's good for you. Do you have a working Bios Floppy file image for LOTEM 400 please ?
  12. J

    Lotem 1, Slammer 0

    After me it seem that com1 and com2 is interchanged and causes Operation "put" of loader local 3 Card failed.
  13. J

    lotem 400 error system (createFile,2)

    Dear all I think my problem come from BIOS which is corrupted, After tested all card, MCF - DDB - NUC - TSP, .. all are correct, only MCF can not load cause of this BIOS error so. I try to reinstall my floppy BIOS disk but it is failed. Can anyone send me a link to download it please? It is a...
  14. J

    lotem 400 error system (createFile,2)

    Thanks for replying me. So I've just checked all fuse on the distribution board, there is no broken, fuse on the transfo back the powerbox, nothing, the drumdriver is correct, all supply breakers are checked and on. All solenoid door are checked and correct, 5v and 24v 115v - 230v is correct...
  15. J

    lotem 400 error system (createFile,2)

    Dear All I need absolutely your help After doing joind Diag, which has correctly done and no problem, In the main window, error message appears immediately after lauching LotemGui E System error [CreateFile,2] E the operation "Put" of Distribution Card" fail E Drum Power Switch Failed dueto...