Recent content by Nickpre123

  1. N

    GMG Epson 9900 Not passing verification or calibration, Max delta E won't drop

    success! After switching the calibration set to the 10c and going through pre-linearization I got a successful calibration. I then had to readjust the roll tension and paper feed adjustment and I'm now getting verifications on both GRACoL and SWOP proofs. thanks for the help.
  2. N

    GMG Epson 9900 Not passing verification or calibration, Max delta E won't drop

    NathanD thanks so much for getting back to me. So I ran another nozzle check and looked at it with a loop and it looks perfect so I don't believe it is a broken nozzle. Resetting the calibration seems like a pretty obvious thing to do not that I'm aware of it! thanks I'm going to reset it back...
  3. N

    GMG Epson 9900 Not passing verification or calibration, Max delta E won't drop

    Hello, So I'm having a bit of trouble getting my 9900 to calibrate and pass verification, and I was hoping someone might have an idea on how I could solve the problem. I'm running GMG ColorProof 5, using a Epson 9900 with Epson ink, and using GMG ProofPaper semiMatte 250. So last week my...