Search results

  1. chock

    Beginers help for Hamada offset

    Hi i have some tech documentation for Hamada. Send me your email or send me email Blessing [email protected] Mobile+WhatsApp:+505 8861 144`1
  2. chock

    Roller replacement

    Hi sir: Your comments are NOT clear, if you look your operator manual, has indication , how to installing very securely, and right for his machine. However, you must do it, with Patience, and carefully in order to damage any New Rollers, and observe the indication coming with the Factory like...
  3. chock

    Beginers help for Hamada offset

    Hi i have some tech documentation for Hamada. Send me your email or send me email Blessing [email protected] Mobile+WhatsApp:+505 8861 144`1
  4. chock

    KBA 105 Rapida with CIPLinkX

    Read carefully, they manuals and software Blessing [email protected] Mobile+WhatsApp:+505 8861 1441
  5. chock

    KBA 105 Rapida with CIPLinkX

    Hi sir: Go this website and download: Manuals Blessing [email protected] Mobile+WhatsApp:+505 8861 1441
  6. chock

    Horizon AC1200 collator fuse?

    Take care when you are changing the Fuses, with the Same type of fuses. 1) the same Voltages example 120Vac, or 220VAC 2) Same rating of Amps: 3amps, same tipe of Amps, NOT less,!! or more. 3) Turn Off the machine totally, for to avoid electrical discharge. 4) Test after replace, if there...
  7. chock

    PT-R4000 E09 ERROR (Irregular 5V power)

    Hi sir: You can easy test the sensor: get your camera cell phone: with the camera cell look the I.R sensor, if is o.k you must look in the camera of cell On , since the human eye CAN not see the I.R spectrum. 2) if is OFF, there are 2 possibilites a) lack of voltage Vdc in the sensor or loose...
  8. chock

    Stahl crossfold rollers setting

    Hi sir: I have some tech documentation for Stahl Roller adjustmen send me the model, and your email, Blessing [email protected] Mobile+WhatsApp:+505 8861 1441
  9. chock

    Hamada 452A MarkII manuals and wiring diagram. year 2000

    Hi sir: I Have some service manual for Hamada, including the B452 electrical s. m Let me know.or send me or give me your email Blessing [email protected] Mobile+WhatsApp:+505 8861 1441
  10. chock

    Horizon AC1200 collator fuse?

    Hi sir: 1) please before to take out the panel 2) check the FUSE: F5 of 2amp, is located in the Main transformer ETG -103B 3) then test the fuses F1+F2= 1amp 4) F3+f4=2 amp all of them located in the secondary of the main transformer ETG Good luck, let me know any question or tech doc...
  11. chock

    Reference position Error in Polar Mohr 66

    Hi sir: Please do the next steps: Cause: The actual position loaded into the control counter when the reference position is passed does not coincide with the reference position stored. The allowance adjusted is also exceeded in this case (default = 0.008 cm). This is caused by the loss of...
  12. chock

    Techorans cut out

    ok, test the steps with the Voltage sir The 1 steps: is test the Power supply Low voltage undervoltage 24V, cause can be control voltage too low 19V, Check the power supply vs the schematic diagrams from your TechnoTran HydroSTAR Compact Alpha.d. and Repair. 2) Look for loose connection...
  13. chock

    Challenge 305 Troubleshooting...

    Hi Good day: Attached is there 3 pages for troubleshooting, in according with the serial number 1994 year. Hope you can fix it. Let me know, sincerely. Blessing [email protected] Mobile+WhatsApp:+505 861 1441
  14. chock

    Challenge 305 Troubleshooting...

    Send me the ID plate of your paper cutter, for to be sure about serial number and year in that way, we must sure. And give me your email please However if your machine does not have the CRT monitor Not apply the instructions, serial number if is from year 1994 must be read 94000D to 94999D ...
  15. chock

    Challenge 305 Troubleshooting...

    Hi sir: Please follow the steps attached, and fix it. However test the battery for low voltage, can be the Big possibility, If you Never replace the back up battery, the information is Lost, and need to Reinstall the software. Let me know, sincerely Blessing [email protected]...
  16. chock

    Techorans cut out

    OK, Let me know sir. Blessing [email protected] Mobile+WhatsApp:+505 8861 1441
  17. chock

    Techorans cut out

    Hi sir: The 1 steps: is test the Power supply Low voltage undervoltage 24V, cause can be control voltage too low 19V, Check the power supply vs the schematic diagrams from your TechnoTran HydroSTAR Compact Alpha.d. and Repair. 2) Look for loose connection, corroded, or broken lines, or...
  18. chock

    Techorans cut out

    waiting details sir Blessing [email protected] Mobile+WhatsApp:+505 8861 1441
  19. chock

    Duplo 4000 collator operators manual wanted

    Waiting your email Blessing [email protected] Mobile+WhatsApp:+505 8861 1441
  20. chock

    Techorans cut out

    ok Thank you Blessing [email protected] Mobile+WhatsApp:+505 8861 1441

PressWise

A 30-day Fix for Managed Chaos

As any print professional knows, printing can be managed chaos. Software that solves multiple problems and provides measurable and monetizable value has a direct impact on the bottom-line.

“We reduced order entry costs by about 40%.” Significant savings in a shop that turns about 500 jobs a month.


Learn how…….

 
Back
Top