Search results

  1. chock

    Heidelberg SM 74 parts

    o.k send me his email. in order to send you the quotation, when i have Blessing
  2. chock

    Heidelberg SM 74 parts

    No idea, send me all total numbers, that i did asked you please Blessing [email protected] Mobile WhatsApp:+505 8861 1441 Managua Nicaragua
  3. chock

    Heidelberg SM 74 parts

    ok Blessing [email protected] Mobile+WhatsApp:+505 8861 1441 Managua, Nicaragua
  4. chock

    Dimension 400

    Hi sir: Sometimes, the plates coming from the factory, out of date. The best way, you can do is to ask the factory, what going on? and explain the fact that they are using from many months ago, without problem, and now? However, you must be sure, that machine is working 100% in the...
  5. chock

    Heidelberg SM 74 parts

    Hi sir; I can supply, parts for Heidelberg, Polar, Stahl. However need 1) serial number machine 2) model 3) parts number 4) delivery country for calculate Freight. Blessing [email protected] Mobile+WhatsApp:+505 8861 1441 Managua, Nicaragua
  6. chock

    bus error in KOMORI (Model GL 240)

    Hi Sir; Will be a good idea Reset the Cpu or Microprocessor. But a) measure the power supply Vcc for the CPU in tolerance 0.7% up or down. b) Clock of CPU in MHZ, if there are o.k, . Otherwise, Will NOT work the RESET for CPU. Sincerely Blessing [email protected]...
  7. chock

    EBM 19 PLC Cutter

    Hi sir: I have some manuals for EMB, and others Let me know, exactly the Model, included some PIC. Blessing [email protected] Mobile+WhatsApp: +505 8861 1441 Managua, Nicaragua. Central America
  8. chock

    ERROR IN Suprasetter A52/A74

    Hi sir; 1) first step, test all power supplies of Vdc in the machine, must be in tolerance 0.7% up or down, example f you are measure; + 5Vdc. and get 5.3 Vdc, the power supply if faulty for TTL circuit. You must replace it or repair, remember there are power supply regulated. and NOT...
  9. chock

    Kluge ehd manual needed

    Waiting sir Send your emaill Thank you in advance, sincerely Blessing [email protected] Mobile+WhatsApp:+505 8861 1441 Managua, Nicaragua, Central America
  10. chock

    Stahl folding

    Hi sir; I have most of the wiring diagrams for Stah models, tech documentation, etc Blessing [email protected] Mobile+WhatsApp;+ 505 8861 1441 Managua, Nicaragua. Central America
  11. chock

    Kluge ehd manual needed

    Send your emaill Thank you in advance, sincerely Blessing [email protected] Mobile+WhatsApp:+505 8861 1441 Managua, Nicaragua, Central America
  12. chock

    Topsetter 74 autoloader error

    The best way, if you are Not sure, Replace it. Happy New Year 🎉 Blessing [email protected] Mobile WhatsApp:+505 8861 1441
  13. chock

    Topsetter 74 autoloader error

    Yes one them, test however both sensors. o.k? Let me know Blessing Happy New Year [email protected] Mobile +WhatsApp; +505 8861 1441
  14. chock

    Topsetter 74 autoloader error

    Hi sir; I can suggest you look in the parts book, the sensor or photo sensor for the plate, is more easy. However attached is there a colection of photo sensors, or sensors, for differents machines or equipment, you must look something like that. Happy New Year [email protected] Mobile...
  15. chock

    Topsetter 74 autoloader error

    Hi sir; You must test the sensor for plate empty, clean it, and look, for loose connector, or loose wires, or dirty wires, or corroded, clean with special electronic contact cleaner. 2) If the probleme persist , after you done the step mentioned before replace sensor 3) you can test the...
  16. chock

    Screen PTR 2000S Error 4213 secondary Scanning motor is illegal.

    Hi sir; Please Reset the CPU in the Motherboard, look for my own schematic for to do it, and example attached. Good look. Merry Christimas, Blessing [email protected] Mobile+WhatsApp:+505 8861 1441
  17. chock

    Chillers - Function and installation.

    Hi sir: What CTP mark do you have? Blessing [email protected] Mobile+WhatsApp:+505 8861 1441
  18. chock

    Topsetter 74 dongle problem

    Hi, you can ask from Heidelberg, or better Westhingouse, or General Electric. Voltage Regulator. Blessing [email protected] Mobile+WhatsApp; +1 505 8861 1441
  19. chock

    Topsetter 74 dongle problem

    Hi , if have problem of power supply Vdc - 5 Vdc, please replace it.,and measure input voltage for VCA, if there are in tolerance 10% up or down, otherwise, adjust the Primary tap of main transformer of machine. However you must review the Input machine, if the Input Voltage is Stable, if NOT...
  20. chock

    ERROR IN Suprasetter A52/A74

    Did you fix it sir? I have complete tech documentation for this machines. Blessing [email protected] Mobile+WhatsApp;+505 8861 1441