Search results

  1. P

    Help with Magnus 800

    Incomprehensible situation. If we send only the plate is 790x1030 (0.3 mm) Magnus works flawlessly. Once sent to the plate 459x525 (0.15 mm), there is a fatal error message (44500 or 44506 or 44501), and after that work is impossible for any type of plates. But if you turn off Magnus for 15-20...
  2. P

    Magnus 800 - can't expose a plate

    We can make a media 790x1030 - no problem. But 459x525... We are getting an error: "The exposure failed. Rcon error: Head command transporter failure (Error Code = 44506, Error category = 07 - Fatal, device cannot recover". The plate unload from the drum (completly OK). But next plates don't...
  3. P

    Staccato 10 mk are really 10 mk?

    What’s size of dot Staccato 10 mk on the printed sheet? Theoretically – 11,5mk (if dot gain 15%)? According to my measurement on the printed sheet (plate reader VIP CAM 122): black, magenta, yellow – about 15-16 mk and cyan – 12 mk. Is it normall?

PressWise

A 30-day Fix for Managed Chaos

As any print professional knows, printing can be managed chaos. Software that solves multiple problems and provides measurable and monetizable value has a direct impact on the bottom-line.

“We reduced order entry costs by about 40%.” Significant savings in a shop that turns about 500 jobs a month.


Learn how…….

 
Back