Thanks for all the help - we're back up and running now. I ordered a new inverter and installed it. I also had to go through and reprogram the parameters on it. The motor was making a noise so I also had to make a call to Mistubishi to tune the inverter. The tech new exactly what parameter...
Regarding the low voltage. I've checked the voltage when it's running at rated speed and when it's not working and I don't notice any difference. I've checked the control voltages, line voltage coming in to the inverter and voltages on the main transformer next to the motor. I agree that it...
This morning when we finally got the machine running - I took the drive belt off and started the machine. The motor ran at rated speed and gave the E-2 error. When I cleared the error and put the belt back on and started the machine it ran at rated speed. Next we turned the power off and back...
There aren't any contactors - but I was wondering if there were some way to test the transformers? There is a large transformer next to the motor - in measuring the voltage coming off it - it's about 5-10% lower than the voltage the label says it should be. How do I test the transformer to see...
Hi! First time post. I'm getting an E-2 error on an ABDick 9995. The Electrical Service Manual says this is a poor encoder z phase input. The machine jogs fine and doesn't cause an error. When pressing the start button (at any speed) the machine will crawl - slower than the normal jog - for...