Search results

  1. VladCanada

    Agfa accuset 1000 plus - several problems

    I think your problem comes from there <<Athlon XP - 512 RAM - 80GB HD - Windows XP - Navigator 7.03 - Plugin Highwater downloaded on the website of Xitron. Tentatod was also HQ Torrent 6.0.>> I mean: you installed incorrect plugin Agfai32
  2. VladCanada

    Agfa accuset 1000 plus - several problems

    You can use the same long APIS cable for Taipan and HW RIPs because APIS protocol of data exchange wrote down in one of the chips installed at HW interface board. APIS cable has only straight wires, no twisted pairs itself. So, if the same cable was good for Taipan RIP when Accuset was...
  3. VladCanada

    Agfa Avantra 44OLP Processor Problem

    No doubts, CPU board, one of Zilog chips passed away or lost contact(s) on the chip's pin(s)
  4. VladCanada

    Agfa Accuset 1000 Calibration hassles

    Forget about "marriage" APIS + HQ RIP APIS board + PrintDrive -> to catch tif files ripped by HQ RIP is the only one solution. For AGFA equipment you will need another interface card to connect with HQ RIP.
  5. VladCanada

    Problem in selectset 44s

    Avantra did not get the signal READY from the film processor. Check the serial cable from the processor to Avantra and both connections at small RJ45-to-DB9 intermediate cable connected to OCP.
  6. VladCanada

    Agfa Accuset 1000 Calibration hassles

    That is absolutely incorrect approach to the solution! On the Density Calibration test you have to find an exposure value which gives you desirable optical (neutral) density: For instance 4.0. and check 50% field for that exposure. In case of Accuset that could be 54 -58% because the Accuset...
  7. VladCanada

    Agfa Avantra 30 spinner shutdown - Error 17

    +1 CSDM problem!
  8. VladCanada

    AGFA LP 82 Ultra Optimum serbia buying a CTP

    Yes, you will be a fish on AGFA's "silver hook". DO NOT start CTP transition of your company from outdated technology. LAP silver-halyde plates - it's time to go out the market! Listen to maxon! Look at processless and chem-free technologies. P.S. There is nothing personal against the Company...
  9. VladCanada

    Thin lines fast scan Avantra 25S

    And I came with the opposite statement to the same verdict :) 75ALS 192 and 195 - signal transmitters and receivers are the part of APIS at DEC board. Internal test OK - basic part of DEC is OK too... but possible APIS problem: PAC/UPAc board, APIS cable (long or short) and APIS chips on the DEC...
  10. VladCanada

    Galileo VS

    200 units - is startpoint for LAP-V, so your idea, what type of plates they use, was correct.
  11. VladCanada

    Galileo VS

    My Customer (VS, 60 mW laser) uses last generation of photopolymer plates and now has 430 exposure value after completed "optics recalibration"
  12. VladCanada

    Galileo VS

    Correct for LAP-V plates, but not for Photopolymer ones.
  13. VladCanada

    Galileo VS

    Question number one: when (last time) did you performed optics cleaning procedure? After that you could start to discuss BOL Sensor sensitivity adjustments and other steps with your local AGFA tech (or other freelancer who is experienced in Galileo).
  14. VladCanada

    Agfa LP68 Ultra processor stays on wait.

    That's not 100% reliable diagnostics. AndroDiag service software created exactly for the last generation of Glunz&Jensen processors (film and plate).
  15. VladCanada

    Agfa LP68 Ultra processor stays on wait.

    What do you use to check all up? AndroDiag?
  16. VladCanada

    Azura Vi

    It's incorrect at all to compare 2 different technologies: photopolymer and "silver". LP-68/72/150 processor remains un-upgradeable for chemfree plates.
  17. VladCanada

    Thin lines fast scan Avantra 25S

    I bet there is 75ALSXXXN transmitters problem at DEC board.
  18. VladCanada

    spinner motor replacement

    To recal...ibrate, not to recall :) If the image of internal test looks like having "Foggy Edges" - that's bad signal for me: you killed Laser Driver Board (actually writing LD) by static discharge from your body.
  19. VladCanada

    spinner motor replacement

    Only BOL (start of line position) parameter needs to be readjusted in case of every step was performed correctly.
  20. VladCanada

    Agfa Selectset 5000 Laser Film Density

    1. SS5000 Density range 0 - 999 (default 550 for 1200 dpi and 350 for 2400 dpi) - your laser has no life at all. 2. Laser assembly. It's possible to replace the Laser only, but by experienced tech 3. Fujifilm is a company name, not a film name - so, the correct answer impossible because of...
Back