    Need help, I'm looking for a service manual for CTP XANTE Speedsetter VM4.

    Vladimir received it from me light years ago :) I also have all possible manuals and software for Xante VM4
  2. C

    CTP Devices Query

    I was working with Cron and Amsky for a few years. Installations, service, training. From both imagers you will have good image on plates. Amsky have better plate centring system. Cron is known for left/right alignment issues because the way they do it. On Amsky you can load and expose the same...
  3. C

    Please help with PTR 4300

    Blocks are moving during drum spin. No other cause. Chris
  4. C

    Screen plate rite 4000 II E4e25 error

    Most probably broken signal cable in black tray between laser head and the rest of the imager. Chris
  5. C

    Please help with PTR 4300

    Take out balancer blocks. Clean with IPA as marked on attached image. If no improvement, check black gum stoppers for wear, if worn just replace rubber pieces. No need to replace whole balancer blocks. Error have nothing to do with balancer flag or sensors. Chris
  6. C

    Any cloud storage users?

    My own cloud. Only positive experience. Chris
  7. C

    Job Interview No No

    Since some time I work as service manager in printing industry. Chris
  8. C

    LF PTR8900N schematic

    Anyone could share please? PM. Thank you. Chris
  9. C

    Help needed - i1pro spectrophotometer, i1profiler, profile maker 5

    I use that version on Win7 with my i1Pro https://www.filemail.com/d/aveyffvzmalrsvq Link valid for one week. Chris
  10. C

    HQ510PC 8.3r0 needed

    PM sent
  11. C

    PLATES NOT REGISTERING AND HAVING LINES ON THE PLATE IMAGE

    Try Ebay maybe. I do not have spare parts for ECRM. Chris
  12. C

    HQ510PC 8.3r0 needed

    Hello Martin. Thank you for reply. Could you share it via Wetransfer? Chris
  13. C

    HQ510PC 8.3r0 needed

    Hello. I need installer for HQ510PC 8.3r0. Wetransfer anyone? Thanks, Chris
  14. C

    HQ510PC 8.3r0 needed

    Hello. I need installer for HQ510PC 8.3r0. Wetransfer anyone? Thanks, Chris
  15. C

    PLATES NOT REGISTERING AND HAVING LINES ON THE PLATE IMAGE

    Movement timeout: • Check drive belts for proper installation and tightness. • Check drive encoder for proper installation; ensure collar is secure on drive shaft. • Run the internal encoder test. • Verify cabling between main drive motors, encoders and main control board • Replace drive...
  16. C

    PLATES NOT REGISTERING AND HAVING LINES ON THE PLATE IMAGE

    There are glass disks inside encoders, might be dirty. Sensors as well. Clean them with photo lens cleaning fluid. No isopropyl alcohol, leaves smudges.
  17. C

    PLATES NOT REGISTERING AND HAVING LINES ON THE PLATE IMAGE

    When online press and hold next/prev/menu While in service menu go to encoders test and execute it.
  18. C

    PLATES NOT REGISTERING AND HAVING LINES ON THE PLATE IMAGE

    So problem with plate transfer still persist. Only cause are motors, belts and tension. You can run encoder test in diagnostics. Laser temp: TEC cooler and cooling fan need to be checked. Chris
  19. C

    PLATES NOT REGISTERING AND HAVING LINES ON THE PLATE IMAGE

    You need to clean ribbon belts both sides. Flat belt and kapton belt. Also brass wheels surface and drive motor shaft. Check tension, should be the same both sides. Clean transport rollers. It is critical for that machine and usually should be done during preventive maintenance every year.
  20. C

    PLATES NOT REGISTERING AND HAVING LINES ON THE PLATE IMAGE

    Lines are in fast scan or slow scan direction?