Recent content by Tron

  1. T

    ManRoland Service in Texas

    Hi Freeman A. Gain, Not sure what you are implying. Honest mistake. I am sure that viclpp will be smart enough to understand that he can call me and I will be more than happy to provide any information he would like.
  2. T

    ManRoland Service in Texas

    Hi Loopyg66, Please give me a call at 630.920.2059 and I will be more than happy to discuss service possibilities in your area. Thanks, Matt Braun Director National Service manroland, Inc.
  3. T

    Manroland Favorit press questions

    If you still have questions you can call 1.800.676.5263 and ask to speak with sheetfed technical support.
  4. T

    Man Roland 202TOB major issue Help please

    Try using the impression for plating.
  5. T

    sheets not forwarding on manroland 300

    Feeder Issue Feeder Issue Hello, I am manroland. The first thing to check is if the output for the vaccuum is turning on. If it is not turning on then the computer is not releasing the output. Typically in this situation the sensors for the pile centering control are not seeing the load or...
  6. T

    Humidity Question

    Your feeding problem does sound like static. We tell our customers that they need to maintain a pressroom humidity level of 50-55%. This is also the spec stated by PIA/GATF. Stock coated on both sides is more likely to be effected by static in a low humidity enviroment. Do you have any anti...
  7. T

    Need Man Roland Parts

    Hi Muddy, Are you in North America? What is actually wrong with the motor?
  8. T

    What is wrong with Roland R300?

    I am not a manroland salesman. I do know about you. Good analog tech. How are you doing after getting shocked on that Heidi press?
  9. T

    What is wrong with Roland R300?

    Wow Freddy you really through manroland under the bus even though you know not what you speak of. I understand you have an axe to grind and have zero experience on digital presses. So let's back up the bus. The electrical nightmare that you speak of is non existant. The use of power...
  10. T

    Inline densitometry

    Hi Cornishpastythighs, I think we are both using English but yours is the Queens and mine is American. Let me rephrase: we are able to scan the entire color bar in three sheets with the inline system. The on cosole system will do this in one sheet. Don't make the trip to Ripley's and yes I work...
  11. T

    Inline densitometry

    Actually there are fundamental differences in the two systems. The Heidi system uses moving scanning heads in the unit to read the sheets. The manroland system uses cameras (no moving parts). All systems watch the trend over many sheets.
  12. T

    Inline densitometry

    You should check out manroland's Inline Color Pilot. This system is faster and more accurate than any other on the market so far. The system is developed by Grapho Metronic who have been in the density measurement business for over 30 years. This system takes three sheets to set the color. I...
  13. T

    Angling Coder Roland 605

    Yeah call IGS. They get their parts from manroland so where do you think the part will be cheaper?
  14. T

    What is wrong with Roland R300?

    With regards to the electrical concerns with the R300.... The only part of the press that is of concern is the CPL system for hanging plates. The press you reference has the Weko control system for CPL. Otherwise the press runs exactly the same electrical package as the R700. The R300 runs the...
  15. T

    initial impression count

    Of course the manufacturer is important. Some presses are assembled and run at the factory prior to installation at the end customer. Some are not prerun.