Search results

  1. S

    Primesetter74 supply cassette direct prob!

    Hi everybody, We'r using Primesetter74. Now a days on time of start up sometimes it don't shows the cassette on monitor. I remove the cassette and put again then detect it. Some time in the time exposé / running condition it don't find the cassette. Sometime it find the cassette again...
  2. S

    Agfa Xcalibur 45S Vaccum Problem

    We'r using Agfa Xcalibur 45S CTP Machine. Recently at the time of Booting it is giving Massage "Vacuum low or missing" boot failed. Error No. J1341 Device - Job level automation. We checked Compressor's air pressure it's ok. Chiller ok. Filters and others is ok. There is no air leak inside...
  3. S

    Signaseter Screen problem

    Hi My Imagesetter(Signasetter) works good except screen problem. When I sent 100% (100X70cm) black image to imagesetter, its output produce startpoint 100% solid but end point becomes 85-90%. And if I send 70% screen, startpoint & endpoint's screen become different (that is start point become...