Search results

  1. O

    Can't access JT's - ApogeeX 4 - Help!

    Hi RVNG I have the same problem in the diskstore. Please could you explain how you've fixed? Regards.
  2. O

    Problem with image in plate at Galileo VXT

    Hi everybody I have the following problem when sending to expose a plate, the entire image is blurry. Take some pictures so you can see how it looks. The problem appeared in the overnight, suddenly. Also send a photo when exposed well. Before: Now: I appreciate any help or advice.
  3. O

    Failure to Detect Plate Edge

    Hi Armya Inc Can you help me with the alignment, I tried but could not.
  4. O

    Failure to Detect Plate Edge

    Hi I have an CTP Agfa Galileo VXT, but when filming an iron command I get the following error message from the console of the galileo, someone who has an idea what could be the problem? Regards.
  5. O

    lp 82 fail of conection

    I have only the problem of automatic exposure you mention.
  6. O

    lp 82 fail of conection

    I commented to review internally the L-Bridge and discovered that he was passed over the sensor output, because of a misplaced iron, now does not give me any error when the processor. Thanks...!!!
  7. O

    lp 82 fail of conection

    How to configure the L-Bridge to the left or right? Directly connect the processor with the engine without the L-Bridge and apparently I was not showing any error, but unfortunately short light and I dont have installed UPS, I could not do the test since it was late and I had to go.
  8. O

    lp 82 fail of conection

    I check the cable 3 times and is good, is the original cable. I found that when I turn conveyor L-Bridge jumping the error in the console.
  9. O

    PLL failed to lock

    I would be very grateful "Armya Inc" if you could send me instructions or steps to resolve this problem. Thanks.
  10. O

    Failure of automatic exposure, CTP Galileo VXT

    VladCanada appreciate your comments when they are useful as any other, but some of your comments have nothing to do, as the case you mention printroot
  11. O

    Failure of automatic exposure, CTP Galileo VXT

    Me too I told you in my country there is no support from Agfa, now if you want to charge me to fix my problem I pay you no problem, but I thought that this is a forum where I can acquire knowledge and also show if any, as any other forum. Now about the alleged thread which explains why I found...
  12. O

    Failure of automatic exposure, CTP Galileo VXT

    When I try to send a test image from the galileo control console of me CTP Galileo VXT I get the following error: Error number: 00DC Device: Carriage Module Description: Failure of automatic exposure Action: Check the parameters of exposure and clean the rotating mirror Check the rotating...
  13. O

    PLL failed to lock

    Today I returned to disassemble the motor to spin the rotor out completely and went back to clean it very carefully, I went back to build and connect and actually sounds much better than it sounded and I no longer get the error of the PLL, but I get another errors with respect to exposure...
  14. O

    PLL failed to lock

    Exactly that happens when I try to manually turn, I hear a squeaking noise and resistance. They know if within the spin motor is somewhere that this vacuum?
  15. O

    PLL failed to lock

    Anyway I disassemble the spin motor and clean the encoder and the mirror, but I still the same error keeps coming out of the PLL. Try to rotate the motor manually but it has some resistance, I wonder if this is normal, or if you have q rotate smoothly? Thanks.
  16. O

    lp 82 fail of conection

    Hi I have the same problem The display of the processor not warn me of any error, but the display of the Galileo program XT Control Consol shows me the following: Error: 1082 Message: "Check the OLP is ready without warnings" Check cable db9 and is good, also check the configuration of ports...
  17. O

    PLL failed to lock

    In my country there is no support from Agfa, and technician bring another country is expensive and slow, if you could guide me or give me some guidelines would appreciate it.
  18. O

    Download Galileo XT Control Console

    No violation of copyright, since software is the original (not cracked), also not all users have all the cds agfa installation and I was a good example as I had to get on my own.
  19. O

    Download Galileo XT Control Console

    Donwload the Galileo XT Control Console v3.04 with Galileo Engine Server 2.60 here: Deposit Files PASS: printroot.com Oz64...!!!
  20. O

    PLL failed to lock

    I have a CTP Galileo VXT, when send a job to fill, show me the next error: "PLL failed to lock" Anyone know what is that error and how resolved?? Thanks.