Search results

  1. L

    Herkules pro

    ERROR 8303 The temperature monitoring of the optics unit reconigzed an error
  2. L

    Ctp lotem 400

    I have a problem the Plotter don´t connect to the RIP I already replace TSP Board, cable to the plotter. The producction manager window doesn´t show... Diagnostics doesn´t show any error. Regards Luis
  3. L

    Lotem 400 can´t connect to plotter

    I need help on this problem, Producction Manager window doesn´t show LotemCalib window also doesn´t show and I get the error Can´t connect to plotter I run all the diagnostics test and NO errors Also I check the laser group and all the 24 laser are ok Also I reload the Xpose software...
  4. L

    ECRM registration problems

    I have an ECRM 56 with registration problems, do you recomend change the capstan motor or it and be adjusted the film drive system.
  5. L

    Avantra 44 Error 82

    Hello everyone!!! Somebody knows what is going on with error 82 Unknown bridge error. this error appears when I try lift the bridge with the OCP command. Also when I run SRAM bridge test with AVDIAG, but sometimes is passed. I already check lift motor, sensors, cables in the bridge, also I...
  6. L

    Avantra 44 and 44S

    Hello friends, somebody update a Avantra 44 to 44S, I think is possible changing the DEC and Spinner. Somebody did it? What do you think are the implications to being succesfull?
  7. L

    ECRM Mako 56 System Error 3

    I have a problems with a ECRM Mako 56 System Error 3 appears frecuently. Also sometimes system error 2 I just replace the main board because in the display appears only black squares with any error information. Now I have all the functions back everything is ok even the film output is ok the...
  8. L

    Avantra 44 Error 154

    I have problem with AGFA Avantra 44S > > Error 154 Diag to DSP Handshake Failed, after that become many errors > codes. > > I try to fix it with AVDIAG RELOADING DSP FlashROM but now in the boot > just before the DSP test appears FF.FF.FF then error 140 DSP H/W HandShake > Error. > > Can...
  9. L

    Output with lines

    I have a problem with AV30, boots with no errors at all. but the output print becomes with hair lines in fastscan direction. First I resolve the problem cooling down the AV (19 C) But now the problem start again. I think is a DEC failure may be in the buffer RAM I think.....:confused:
  10. L

    Herkules error

    I have a problem with a Herkules, during film loading error 350B Controller Material.:(
  11. L

    AVANTRA 44 error 139

    I have this error 139 Cannot switch K4 to Master Mode. Also I noticed I don´t have any signal from SDM Board for example I leave the covers of the drum open and the Av didn´t stop the spin motor start, no error 13, before of 139 the error was 13 with the covers closed. I already check the sdm...
  12. L

    Error 13

    I have an error 13 (left door open) on AV44. I already check the switch is OK, cables, conector to SDM Board everything is OK, even I check with another SDM Board and the error still . I check disconecting the cable from DEC to SDM the error 13 still the same. I suspect the problem is with my...
  13. L

    registration problems AV44

    I have a AV44S with registration problems, also it have a overimage (20% goes to 90% or more) like the film is not complete adhered to the drum but only a wrinkled. I check vacum line it´s ok 13 in/hg, the suction on the film a seems ok:confused:
  14. L

    Av30 vacum problems

    :confused:I have lost of vacum, I already check the vacum pump alone is 15 with the vacum system connected drops to 2, I replace all the hoses but I saw the problem is between the punch assembly and drum is a rubber gasket but I cant find the original replacement somebody have the exact size of...
  15. L

    Ctp galileo ve with lp-82

    I want to buy a Galileo VE the people who offer this CTP told me this model (2005) have a 60mW laser to expose Violet Photopolymer plates because I want this kind of plates, the question is can I use the LP-82 Processor, do I have to do any changes to the processor. Also I want to use a FUJI...
  16. L

    Avantra 30 OLP

    I have problems with the bridge of my AV30, because the film goes to fast to the processor and sometimes the film jam just betewn the bridge and processor input and every time the film practically hits with the first rollers of processor input. I tried to use a AVDIAG to control the speed or get...
  17. L

    Avantra 30 problem

    I had an AV30 on service, with a DEC board failed to boot. I got an used DEC board, now the machine boots ok, but when I try to film error 41 appears (bridge not in possition) but I´m sure bridge is in possition very lowered . Then I run the AVDIAG to check the sensors, but in the first screen...

PressWise

A 30-day Fix for Managed Chaos

As any print professional knows, printing can be managed chaos. Software that solves multiple problems and provides measurable and monetizable value has a direct impact on the bottom-line.

“We reduced order entry costs by about 40%.” Significant savings in a shop that turns about 500 jobs a month.


Learn how…….

 
Back
Top